A passive-building standard seeks very low energy demand while maintaining comfortable indoor conditions. It is a performance target, not a single architectural style or a rule that a building uses no heating. The design begins by reducing unwanted heat flow through a well-insulated enclosure, high-performance windows, and careful treatment of junctions that would otherwise form thermal bridges. Compact form can help, but orientation and shading also influence gains from the sun. Because climate, occupancy, and building size differ, compliance is assessed through calculated demand and airtightness rather than by counting visible green features such as solar panels or timber finishes.

Paragraph B

Airtight construction limits uncontrolled leakage through cracks, but occupants still need fresh air. Balanced mechanical ventilation supplies outdoor air and removes stale air through separate ducts. A heat-recovery core transfers energy between the outgoing and incoming streams without mixing them directly, reducing the heating or cooling needed for ventilation. Filters can remove particles from supply air, provided they are changed and the system is commissioned properly. Opening a window is not forbidden; doing so merely bypasses heat recovery while it remains open. The principle is controlled ventilation, not sealing people inside a building, and poor maintenance can undermine an otherwise efficient enclosure.

Paragraph C

Design must respond closely to local climate. In a cold region, solar gain and heat recovery may reduce winter demand, but large unshaded windows can cause summer overheating. In a hot, humid climate, shading, moisture control, and efficient cooling may matter more than winter solar gain. Internal heat from people, lights, and equipment becomes significant when the envelope loses little energy. Models therefore use assumptions about occupancy and appliances, and designers test future hot-weather scenarios. A building can meet an annual energy target yet still be uncomfortable for a few dangerous weeks, so peak temperature and humidity require separate attention.

Paragraph D

Construction quality is verified through pressure testing and inspection because small gaps hidden behind finishes can cause disproportionate leakage. The additional design and component costs may be partly offset by smaller heating equipment and lower operation, but savings vary with energy prices and workmanship. Retrofitting an existing building is harder when balconies, foundations, or heritage facades create unavoidable thermal bridges. Some projects use a staged approach, coordinating windows and ventilation now with later insulation. Measured performance after occupancy remains essential: controls may be confusing, filters may clog, and actual schedules may differ from the model. Certification predicts and tests performance; it does not suspend the need to operate the building well.

Paragraph E

Not given in any of the above paragraphs.

Decide which paragraph, A to D, has the information given in each statement below. Select E if the information is not given in any of the paragraphs.

  1. Opening windows temporarily sacrifices heat recovery without violating the standard.
  2. A tighter envelope magnifies the temperature influence of internal equipment loads.
  3. Meeting an annual energy target guarantees comfortable peak summer conditions.
  4. Certification rests on quantified envelope performance, not conspicuous environmental features.
  5. Staged retrofits require present components to anticipate later envelope work.
  6. Certification cannot replace measurement when operation diverges from modelling.
  7. Post-finish pressure tests chiefly verify exterior insulation against façade specifications.
  8. Heat recovery transfers energy between separate air streams without recirculating exhaust.
  9. Certification evaluates measurable demand and airtightness rather than architectural appearance.
0 of 9 answered

Answer key

Show all 9 answers
  1. Opening windows temporarily sacrifices heat recovery without violating the standard. B
  2. A tighter envelope magnifies the temperature influence of internal equipment loads. C
  3. Meeting an annual energy target guarantees comfortable peak summer conditions. E
  4. Certification rests on quantified envelope performance, not conspicuous environmental features. A
  5. Staged retrofits require present components to anticipate later envelope work. D
  6. Certification cannot replace measurement when operation diverges from modelling. D
  7. Post-finish pressure tests chiefly verify exterior insulation against façade specifications. E
  8. Heat recovery transfers energy between separate air streams without recirculating exhaust. B
  9. Certification evaluates measurable demand and airtightness rather than architectural appearance. A